Buying guide

How to Calculate CFM for a Range Hood

Updated on · By the Got Vents team

Calculate range hood CFM by multiplying your cooktop's width in feet by 100 for a gas stove, or by 10 per square foot of kitchen for an electric one. Then add about 25 percent for each 90-degree elbow or long duct run, and keep the final number within your duct's real capacity.

On this page (10 sections)
  1. What is the basic CFM formula for a range hood?
  2. How do you calculate CFM for a gas cooktop?
  3. How do you calculate CFM for an electric cooktop?
  4. What duct corrections change the CFM you need?
  5. Which hood ratings match the base CFM figures?
  6. How does kitchen size change the answer?
  7. How do you handle the makeup air rule?
  8. What else affects the CFM you actually get?
  9. How do you check a hood's rating before buying?
  10. Which of these hoods should you pick?

To learn how to calculate CFM for a range hood, start with one number: the width of your cooktop in feet, multiplied by 100 for a gas stove. For an electric or induction range, use 10 CFM per square foot of kitchen instead.

Then adjust that base figure upward for long duct runs, bends and high altitude, and compare it to the hood's published rating.

The formula is only the first step. A hood rated for 900 CFM on a 4-inch duct cannot move that much air, so the duct you already have sets your real ceiling.

This guide walks through the math for both fuel types, the duct corrections that matter, and how to match a rating to the hoods on the market.

What is the basic CFM formula for a range hood?

The basic range hood CFM formula uses 100 CFM per foot of gas cooktop width, or 10 CFM per square foot of kitchen for an electric cooktop. Take the larger number if both methods apply, then round up to the nearest standard rating.

Cooktop typeFormulaExampleBase CFM
GasWidth in feet x 10030 in wide (2.5 ft)250
Electric or inductionKitchen square feet x 1010 x 12 ft kitchen120

For a 30-inch gas range, 2.5 feet times 100 gives 250 CFM. A 36-inch gas cooktop is 3 feet wide, so the base figure rises to 300 CFM.

The square-footage method looks at the room the hood has to clear: a 120-square-foot kitchen needs about 120 CFM, well under most hoods sold today.

Why the two methods disagree

The width method sizes the hood to the cooking surface. A wide gas cooktop throws heat and smoke across a broad area, so the hood has to span it and pull hard enough to catch what rises.

The square-footage method sizes the hood to the room, assuming the hood clears the kitchen's air rather than the plume above the burners. For electric cooking with modest heat, that is usually enough.

When the numbers differ, use the larger one. A 250 CFM base is easy to hit; a 300 CFM base on a 36-inch gas cooktop starts to depend on the duct being straight and wide enough.

If you want a walkthrough that starts from your range rather than the room, our range hood CFM sizing guide covers the same math with different worked examples. The formula here is the short version.

Rule: calculate both figures, keep the larger, and round up to the next standard rating.

How do you calculate CFM for a gas cooktop?

Use cooktop width in feet times 100, measured across the burner span, not the whole appliance. A 30-inch gas range gives 2.5 x 100 = 250 CFM, and a 36-inch gives 3 x 100 = 300 CFM.

That base figure assumes a straight, short duct.

Measure the burner area rather than the outer edge of the range if the two differ. Some ranges have a wider frame than their burner spread, and the hood needs to cover the burners.

The 100-per-foot rule is a benchmark, not a code requirement. It reflects the heat load of open gas flames, which push more exhaust upward than electric elements.

High-BTU burners and wok rings can justify more.

A hood for a gas cooktop should also span the full burner width or a little more. Width and airflow work together: an undersized hood on a wide gas range lets smoke escape at the edges no matter how many CFM it claims.

Our roundup of the best range hoods for gas cooktops shows how the models differ in width and rating. Most 30-inch hoods land in the 250 to 900 CFM range, which covers the base figures above.

Our CFM requirement guide compares the gas and electric methods side by side if you are still deciding between formulas.

Rule: a 30-inch gas range needs at least 250 CFM, and a 36-inch needs at least 300 CFM before duct corrections.

How do you calculate CFM for an electric cooktop?

For electric and induction ranges, use 10 CFM per square foot of kitchen floor area, or the width rule if you prefer consistency. A 120-square-foot kitchen gives 120 CFM; a 200-square-foot kitchen gives 200 CFM.

Electric cooking needs less because there is no open flame.

Measure the kitchen's length and width in feet and multiply them. Include the area the hood serves, not adjoining rooms behind a doorway.

An open-plan kitchen that shares air with a living room should be measured on its own footprint.

The width method still applies as a sanity check. A 30-inch electric cooktop gives 2.5 x 100 = 250 CFM, which is higher than the square-footage figure for most kitchens.

An electric hood rated at 250 CFM or more clears both tests. Induction cooktops run cooler on the surface than coil or radiant electric, but they still produce steam and odors.

Treat them like electric.

Many 30-inch hoods sold today sit between 250 and 900 CFM. A modest electric kitchen rarely needs the top of that range unless the duct run is long or the cooking is heavy.

Rule: for electric cooking, size by square footage, but keep the width figure in reserve if the kitchen is large.

What duct corrections change the CFM you need?

Duct corrections add to the base figure when the run is long or has bends. Add about 25 percent for each 90-degree elbow past the first, and about 25 percent for every 25 feet of extra straight duct.

A short, straight vent needs no correction.

Duct conditionAdjustment to base CFM
Straight run under 10 feetNone
One extra 90-degree elbowAdd about 25%
Two extra 90-degree elbowsAdd about 50%
Every additional 25 feet of straight ductAdd about 25%

Airflow drops when air has to turn or travel far. A hood rated for 400 CFM may deliver noticeably less at the vent opening on a run with several bends.

Duct diameter matters just as much. A 4-inch round duct carries far less air than a 6-inch or 3-1/4 x 10-inch rectangular duct.

If your cabinet and wall already have a 4-inch opening, a very high CFM hood will be throttled by that opening.

Altitude also thins the air. Above roughly 2,000 feet, many makers recommend sizing up, so read the hood's documentation for your elevation before choosing a rating.

For a compact kitchen with a short vent, these corrections rarely push you past 400 CFM. Our post on whether 400 CFM is enough shows when that rating covers a gas or electric range.

Rule: add 25 percent per extra elbow or per 25 feet of duct, and never buy a hood whose rating exceeds what the duct can pass.

Which hood ratings match the base CFM figures?

Once you have a corrected CFM figure, match it to a hood whose published rating meets or slightly exceeds it. Three 30-inch under-cabinet models cover the low, middle and high end of the typical range.

ModelWidthPublished airflowBest fit for
Hauslane UC-PS6029-3/4 in450–860 CFMMost gas and electric kitchens with a normal duct
AMZCHEF 30 in Stainless29.8 in750 CFMMedium to large kitchens with a straight run
VIKIO HOME RC1329.5 in900 CFMHeavy cooking and long or multi-bend ducts

Hauslane UC-PS60: the flexible middle

The Hauslane UC-PS60 spans 450 to 860 CFM across three fan speeds, so you can run it low for a quick boil and high for a sear. Its 29-3/4-inch width covers a standard 30-inch gas or electric range with a little margin.

The VersaVent system includes a 6-inch round adapter and 3-1/4 x 10-inch rectangular adapters for top or rear venting. That range of options means the hood can connect to whatever opening the cabinet provides.

A concave baffle filter captures grease and is dishwasher safe, and Hauslane backs the motor with a lifetime warranty. Its 7-sone noise figure at the top end is a real trade-off, so plan to run lower speeds for everyday cooking.

Pick the Hauslane if your corrected CFM figure falls between 450 and 860 and you want one hood that adapts to the duct opening.

AMZCHEF 30 in Stainless: the mid-range workhorse

The AMZCHEF moves up to 750 CFM, which clears most 30-inch gas ranges even after one or two duct corrections. It fits a 29.8-inch cabinet opening and uses a 6-inch round outlet.

Three fan speeds let you step down for simmering. The remote and touch controls add convenience, and the timer function is useful for a long braise or a bake.

Two LED lamps light the cooktop. Its 430 stainless steel body resists deformation and helps keep oil and smoke from seeping into the motor housing.

The 63 dB noise figure sits in the middle of the three, not a whisper but not the loudest either.

Pick the AMZCHEF if you want solid airflow for a typical gas range and remote control is useful to you.

VIKIO HOME RC13: the high-output option

The VIKIO HOME RC13 is rated up to 900 CFM with dual motors, the highest rating in this group. It suits a 30-inch range that sees frequent high-heat cooking: stir-frying, searing steak or indoor grilling.

VIKIO HOME says it clears grease, steam and odors from a 150-square-foot kitchen in about 120 seconds. Its DC motor runs as low as 35 dB on the lowest speed and stays under 65 dB at full power.

Gesture control lets you change speeds with a wave when your hands are messy, and the memory function restores your last setting. A 5-layer aluminum mesh filter is dishwasher safe.

The 900 CFM rating only counts if the duct can pass it.

Pick the VIKIO if your corrected figure approaches 900 CFM and the duct run is short and wide.

How does kitchen size change the answer?

Kitchen size matters most for electric cooking and open-plan layouts, where the room's air volume sets the base figure. A 120-square-foot kitchen needs about 120 CFM; a 300-square-foot open kitchen needs about 300 CFM.

The bigger the space, the more the square-footage method takes over from the width rule.

Measure the cooking zone's footprint first. In an open-plan kitchen, include the full area the hood serves, but do not add rooms behind a wall or doorway.

High ceilings change the calculation too. A kitchen with a 12-foot ceiling holds more air than one with an 8-foot ceiling at the same floor area, so a vaulted room may need a step up.

The width method still caps the answer from below. Even a large kitchen needs a hood that spans the burners.

For a 30-inch range in a 300-square-foot kitchen, the base figure is 300 CFM; for a 36-inch range, it is 360 CFM. If the two figures disagree sharply, the larger one is the safer base.

Then apply the duct corrections from the previous section before you buy.

Rule: size by square footage for electric cooking and by burner width for gas, then keep the larger figure.

How do you handle the makeup air rule?

The makeup air rule applies when a hood exhausts 400 CFM or more in a tightly built home. The International Residential Code requires a makeup air system in that case so the house does not depressurize.

Most 30-inch hoods on low and middle speeds fall below the threshold.

Here is the practical sequence. Find your corrected CFM figure.

Check whether the final rating you plan to buy is 400 CFM or more. If it is, look at how airtight your home is, because newer homes with tight envelopes and sealed windows are the ones that need makeup air.

Then talk to your installer about a makeup air damper or an interlocked supply fan.

Older homes with leaky envelopes often pass enough air through gaps and vents without a dedicated system. That does not make the rule go away; it changes how much risk the installer sees.

The rating on the box is the maximum, not what you use every day. A hood rated 900 CFM may spend most of its life on low speed, where it moves far less air.

The code looks at the appliance's potential exhaust, so the rating still counts.

For a small kitchen with a 30-inch hood, a corrected figure under 400 CFM is common. Our guide to whether 400 CFM is enough walks through when you can stop there.

Rule: if your final rating reaches 400 CFM, ask your installer about makeup air before installation.

What else affects the CFM you actually get?

Several factors beyond the formula decide how much air a hood really moves. Duct diameter, duct length, the number of bends and altitude all reduce real airflow from the rated figure.

A hood's rating is measured under ideal test conditions.

A 6-inch round duct or a 3-1/4 x 10-inch rectangular duct carries much more air than a 4-inch round duct. A hood rated 400 CFM on a 4-inch duct may move closer to 250 CFM in practice.

Length and bends come next. Every 90-degree elbow adds resistance, and so does every extra stretch of straight duct.

Short and straight beats long and crooked, whatever the rating.

Altitude matters above roughly 2,000 feet. Thinner air carries less heat and smoke, and many makers recommend sizing up.

Check the hood's own guidance for your elevation.

Finally, consider how you cook. High-heat methods like searing and stir-frying produce more smoke and grease than simmering or baking.

A 250 CFM base might cover gentle cooking but fall short for a wok burner. If you cook heavy and often, aim for the top of your corrected range.

Our roundup of the best hoods for gas cooktops shows which models reach the high end.

Rule: never choose a rating you cannot feed with a wide, short, straight duct.

How do you check a hood's rating before buying?

Compare the published CFM figure at its highest speed against your corrected number, then check the duct adapter size and the noise rating. A rating only counts if the duct opening matches it and the noise stays tolerable.

Check five things on each model. Look for the maximum CFM at the top fan speed, ideally a range like 450–860 rather than a single peak number.

Confirm the duct adapter sizes included, since a 6-inch round or 3-1/4 x 10-inch rectangular opening is more useful than a 4-inch one. Note the noise figure, often in sones or decibels, because high CFM usually costs some quiet.

Check the number of speeds so you can step down for everyday cooking. Then look at the filter type: baffle and mesh filters both capture grease, and both are easier to live with when dishwasher safe.

If your corrected figure is 250 CFM and the hood's top rating is 900 CFM, you do not have to run it flat out. The extra headroom lets you run it lower and quieter for most meals.

If the hood's adapter is smaller than your duct, airflow will suffer, so match the opening first. Our CFM sizing guide covers the adapter match in more detail.

Rule: match the duct adapter to your vent opening before you compare CFM ratings.

Which of these hoods should you pick?

Match the hood to your corrected CFM figure and your duct opening. For most 30-inch gas and electric kitchens with a normal duct, the Hauslane UC-PS60 is the pick.

Its 450–860 CFM range covers the base figures from this guide with headroom and adapts to top, rear or round venting.

Pick the AMZCHEF 750 CFM when your figure sits in the middle and you want remote control. Its 750 CFM rating clears most corrected 30-inch gas figures without running at full power.

Choose the VIKIO HOME RC13 when your corrected figure approaches 900 CFM and the duct is short and wide. Its dual motors suit frequent high-heat cooking.

Here is the short version of how to calculate CFM for a range hood: take the burner width in feet times 100 for gas or the kitchen square footage times 10 for electric, keep the larger figure, and add 25 percent for extra elbows or long duct. Then compare that number to a hood's top rating and its duct adapter size.

If the final figure lands near 400 CFM, read whether 400 CFM is enough before you buy. For gas ranges specifically, the gas cooktop hood roundup shows which models match the higher base figures.

Rule: pick the hood whose top rating meets your corrected figure and whose duct adapter fits your vent opening.

Frequently asked questions

Does a higher CFM rating always mean better venting?

No. A high-rated hood on a narrow or crooked duct can move less air than a smaller hood on a straight 6-inch run.

The duct, the number of elbows and the total length cap what any hood can actually pull.

How much CFM do I add for elbows in the duct?

Add about 25 percent to the base figure for each 90-degree elbow beyond the first, and about the same for every 25 feet of extra straight duct. A short, straight run needs no adjustment.

Does the makeup air rule apply to my kitchen?

The 400 CFM makeup air threshold in the International Residential Code applies to exhaust appliances in tightly built homes. Small kitchens with a 30-inch hood usually land below it, so a standard hood is fine for most homes.

Do I need more CFM for a gas range than an electric one?

Yes. Gas burners put out more heat and combustion byproducts than electric coils or induction, so the width-times-100 rule gives gas cooktops a higher base figure than the square-footage method gives electric ones.